The original roof-penetrating hydrant: a 24" freeze-proof hose station that meets ASSE 1057 Sanitary Yard Hydrant standards, with the supply connection made inside the conditioned space below the roofline.
Need a submittal for a model that is not listed? Ask MAPA and we will send it.
MPH-24FP (drain-down). Operates on the venturi principle. When the hydrant is off, the stopper seals against the nozzle and water in the riser drains back into a reservoir tank in the conditioned space below the roof. When the hydrant is on, flow through the nozzle creates a vacuum that evacuates the reservoir through the hydrant.
MPH-24D (auto-drain). Uses a full-port ball valve with an auto-drain port below the freeze line at the base of the hydrant. Water remaining in the standpipe discharges through field-provided piping to an open drain below the roofline.
| Valve assembly | 125 psi ¾" ball valve; male hose fitting with quick disconnect |
|---|---|
| Drain | Loose-fit wye strainer for field installation |
| Handle | Black powder-coated cast aluminum Weather-Guard dome |
| Shroud | Grade 304 stainless with welded stainless flange |
| Insulation | R-8 Thermo-Cell |
| Mounting | Black powder-coated under-deck support flange with hardware |
| Option | Deck cap, suffix D |